Cornell University
Library
Cornell UniversityLibrary

eCommons

Help
Log In(current)
  1. Home
  2. College of Engineering
  3. Civil and Environmental Engineering
  4. Laboratory Earthquakes from the Cornell 3 m apparatus
  5. Data from: Seismic swarms produced by rapid fluid injection into a low permeability laboratory fault

Data from: Seismic swarms produced by rapid fluid injection into a low permeability laboratory fault

File(s)
Cebry_EPSL2020_Readme.txt (7.04 KB)
Cebry_EPSL2020_Data.zip (1.28 GB)
Permanent Link(s)
https://doi.org/10.7298/enph-mx14
https://hdl.handle.net/1813/102716
Collections
Laboratory Earthquakes from the Cornell 3 m apparatus
Author
Cebry, Sara Beth L.
McLaskey, Gregory C.
Abstract

These data are from Laboratory Earthquake Experiments from the Cornell 0.76 m apparatus in support of the following research: Fluid injection, from activities such wastewater disposal, hydraulic stimulation, or enhanced geothermal systems, decreases effective normal stress on faults and promotes slip. Nucleation models suggest the slip at low effective normal stress will be stable and aseismic—contrary to observed increases in seismicity that are often attributed to fluid injection. We conducted laboratory experiments using a biaxial loading apparatus that demonstrate how an increase in fluid pressure can induce “stick-slip” events along a preexisting saw-cut fault in a poly(methyl methacrylate) (PMMA) sample. We compared slip events generated by externally squeezing the sample (shear-triggered) to those due to direct fluid injection (fluid-triggered) and studied the effects of injection rate and stress levels. Shear-triggered slip events began on a localized nucleation patch and slip smoothly accelerated from slow and aseismic to fast and seismic. Fluid-triggered slip events initiated far more abruptly and were associated with swarms of tiny foreshocks. These foreshocks were able to bypass the nucleation process and jump-start a mainshock resulting in an abrupt initiation. Analysis of these foreshocks indicates that the injection of fluid into a low permeability fault promotes heterogeneous stress and strength which can cause many events to initiate—some of which grow large. We conclude that while a reduction in effective normal stress stabilizes fault slip, rapid fluid injection into a low permeability fault increases multi-scale stress/strength heterogeneities which can initiate small seismic events that have the potential to rapidly grow, even into low stress regions.

Sponsorship
This work was sponsored by National Science Foundation grant EAR-1847139.
Date Issued
2020-12-18
Keywords
hydraulic stimulation
•
laboratory earthquake
•
diffusivity
Rights
CC0 1.0 Universal
Rights URI
http://creativecommons.org/publicdomain/zero/1.0/
Type
dataset

Site Statistics | Help

About eCommons | Policies | Terms of use | Contact Us

copyright © 2002-2026 Cornell University Library | Privacy | Web Accessibility Assistance