Cornell University
Library
Cornell UniversityLibrary

eCommons

Help
Log In(current)
  1. Home
  2. Weill Cornell Medicine
  3. Medical College Research and Papers
  4. Department of Otolaryngology - Head and Neck Surgery
  5. Accuracy of Balloons and Handheld Spirometers as Low-Cost Tools for Measuring Vital Capacity and Air Volume: A Laboratory-Based Validation Study

Accuracy of Balloons and Handheld Spirometers as Low-Cost Tools for Measuring Vital Capacity and Air Volume: A Laboratory-Based Validation Study

Access Restricted

Access to this document is restricted. Some items have been embargoed at the request of the author, but will be made publicly available after the "No Access Until" date.

During the embargo period, you may request access to the item by clicking the link to the restricted file(s) and completing the request form. If we have contact information for a Cornell author, we will contact the author and request permission to provide access. If we do not have contact information for a Cornell author, or the author denies or does not respond to our inquiry, we will not be able to provide access. For more information, review our policies for restricted content.

File(s)
41591963.pdf (2.51 MB)
No Access Until
2027-01-27
Permanent Link(s)
https://hdl.handle.net/1813/124358
Collections
Department of Otolaryngology - Head and Neck Surgery
Author
Curtis, J.A.
Grasso, M.
Jagdhar, B.
Abstract

INTRODUCTION: Vital capacity and air volume are key physiological substrates important for voice, speech, cough, and swallowing. The current gold standard equipment to assess vital capacity and air volume is a pneumotachograph. The aim of this study was to characterize the validity of four low-cost, clinically accessible tools as potential alternative methods to accurately assess vital capacity and air volume. METHODS: This laboratory-based study examined the accuracy of four low-cost tools to assess vital capacity and air volume: two balloon-based circumference methods (<$1 USD), one analogue spirometer (~$100 USD), and one consumer-grade digital spirometer (~$150 USD). In Experiment 1, known volumes of air (ground truth) were injected into each low-cost tool using a 3-liter calibration syringe. In Experiment 2, the same tools were tested against gold standard pneumotachography equipment. Agreement was assessed using descriptive statistics, Lin's concordance correlation coefficient (ρc), Bland-Altman plots, and linear regression models. Concordance was interpreted as 'moderate' if ρc = 0.90 - < 0.95, 'substantial' if ρc = 0.95 - < 0.999, and 'excellent' if ρc ≥ 0.999. RESULTS: All four tools showed substantial agreement with the ground truth and gold standard measurements. Median absolute differences ranged from 0.07-0.29 liters across tools. The digital spirometer demonstrated the highest agreement, with ρc ≥ 0.994 and the lowest absolute error. While balloon-based methods showed greater variability due to geometric deviations, accuracy improved significantly when correction factors from regression models were applied. CONCLUSION: The findings support the use of balloon-based circumference techniques, analogue spirometry, and digital spirometry as low-cost alternatives for measuring vital capacity. Each tool demonstrated predictable error patterns that could be corrected to yield highly accurate estimates. These results may expand access to vital capacity measurement in outpatient, home health, and resource-limited settings.

Journal / Series
Folia phoniatrica et logopaedica : official organ of the International Association of Logopedics and Phoniatrics (IALP)
Date Issued
2026-01-27
Publisher
Karger Publishers
Keywords
WCM Library Coordinated Deposit
•
Assessment
•
Balloon
•
Feasibility
•
Validity
•
Vital capacity
Related DOI
https://doi.org/10.1159/000550710
Previously Published as
Curtis JA, Grasso M, Jagdhar B. Accuracy of Balloons and Handheld Spirometers as Low-Cost Tools for Measuring Vital Capacity and Air Volume: A Laboratory-Based Validation Study. Folia phoniatrica et logopaedica : official organ of the International Association of Logopedics and Phoniatrics (IALP). 2026;:1-12. doi: 10.1159/000550710. PMID: 41591963.
Rights
Attribution-NonCommercial-NoDerivatives 4.0 International
Rights URI
https://creativecommons.org/licenses/by-nc-nd/4.0/
Type
article

Site Statistics | Help

About eCommons | Policies | Terms of use | Contact Us

copyright © 2002-2026 Cornell University Library | Privacy | Web Accessibility Assistance