<?xml version='1.0' encoding='UTF-8'?><?xml-stylesheet href='static/style.xsl' type='text/xsl'?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-22T09:33:15Z</responseDate><request verb="GetRecord" identifier="oai:ecommons.cornell.edu:1813/38778" metadataPrefix="dim">https://ecommons.cornell.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:ecommons.cornell.edu:1813/38778</identifier><datestamp>2026-05-14T13:50:11Z</datestamp><setSpec>com_1813_35</setSpec><setSpec>col_1813_47</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Dorta Quinones, Carlos</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="chair" lang="en_US">Apsel, Alyssa B.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="committeeMember" lang="en_US">Molnar, Alyosha Christopher</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="committeeMember" lang="en_US">Lindau, Manfred</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2015-01-07T20:57:07Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2019-08-19T06:01:03Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2014-08-18</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://hdl.handle.net/1813/38778</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="bibid">8793274</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Dopamine is an important neurotransmitter that plays a fundamental role in motor control and reward-seeking behaviors. Electrochemical detection of dopamine is accomplished through fast-scan cyclic voltammetry (FSCV), a neurochemical monitoring technique that can resolve rapid changes in dopamine concentration with subsecond temporal resolution and high selectivity. This dissertation describes the development of several microsystems for real-time monitoring of dopamine levels using FSCV, including a wide-range analog-todigital converter (ADC), a fully-integrated low-power wireless sensing system, and a scalable electrochemical detector array. The work described here tackles some of the challenges that exist in the field of neuroscience to advance two important applications: long-term in vivo monitoring in freely-behaving animals using carbon-fiber microelectrodes (CFMs) and high-throughput drug screening using planar microelectrode arrays (MEAs). In particular, a low-power two-step cyclic ADC for wide-range acquisition of neurochemical signals is demonstrated. The system was validated by recording flow-injection of 2-[MICRO SIGN]M dopamine at a CFM using 300-V/s FSCV. A 30-[MICRO SIGN]W wireless microsystem for real-time in vivo monitoring and a lightweight miniaturized device that can enable long-term behavioral studies in freely-behaving animals are also demonstrated. On-chip integration of analog background subtraction and UWB telemetry yields a 32-fold increase in resolution versus stan-  dard Nyquist-rate conversion alone, near a four-fold decrease in the volume of uplink data versus single-bit, third-order, delta-sigma modulation, and more than a 20-fold reduction in transmit power versus narrowband transmission at low data rates. The system was validated by wirelessly recording flow-injection of dopamine with concentrations in the range of 250 nM to 2 [MICRO SIGN]M at a CFM using 300-V/s FSCV. Measurement results indicate an input-referred current noise of 92 pArms and an input current range of ±430 nA at a conversion rate of 10 kHz. A scalable 32 x 32 (1,024-electrode) CMOS VLSI potentiostat array for highthroughput drug screening applications is also presented. The core of the array is a high-precision bidirectional-current detector that enables both amperometry and FSCV using MEAs for massively-parallel detection of transmitter release as well as electrode impedance characterization.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">en_US</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">neurochemical monitoring</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">fast-scan cyclic voltammetry</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">dopamine detection</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Microsystems For Real-Time Neurochemical Monitoring Using Fast-Scan Cyclic Voltammetry</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">dissertation or thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="thesis" element="degree" qualifier="discipline">Electrical Engineering</dim:field>
   <dim:field mdschema="thesis" element="degree" qualifier="grantor" lang="en_US">Cornell University</dim:field>
   <dim:field mdschema="thesis" element="degree" qualifier="level">Doctor of Philosophy</dim:field>
   <dim:field mdschema="thesis" element="degree" qualifier="name">Ph. D., Electrical Engineering</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="cris" element="virtual" qualifier="collection" authority="https://cornell-ecommons.eks.prod.4science.cloud/handle/1813/47" confidence="600">Cornell Theses and Dissertations</dim:field>
   <dim:field mdschema="cris" element="virtual" qualifier="author" lang="en_US">Dorta Quinones, Carlos</dim:field>
   <dim:field mdschema="cris" element="virtualsource" qualifier="collection">5893a6ea-7af3-41d7-abc6-04bcd26ab5df</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="54ff920c-b180-456e-bd95-48f3fda35269">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>en_US&lt;/Language>
   	&lt;Title>Microsystems For Real-Time Neurochemical Monitoring Using Fast-Scan Cyclic Voltammetry&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2014-08-18&lt;/PublicationDate>
   	&lt;Authors&gt;
      	&lt;Author>
        	&lt;DisplayName>Dorta Quinones, Carlos&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;Keyword>neurochemical monitoring&lt;/Keyword>
    &lt;Keyword>fast-scan cyclic voltammetry&lt;/Keyword>
    &lt;Keyword>dopamine detection&lt;/Keyword>
   	&lt;Abstract>Dopamine is an important neurotransmitter that plays a fundamental role in motor control and reward-seeking behaviors. Electrochemical detection of dopamine is accomplished through fast-scan cyclic voltammetry (FSCV), a neurochemical monitoring technique that can resolve rapid changes in dopamine concentration with subsecond temporal resolution and high selectivity. This dissertation describes the development of several microsystems for real-time monitoring of dopamine levels using FSCV, including a wide-range analog-todigital converter (ADC), a fully-integrated low-power wireless sensing system, and a scalable electrochemical detector array. The work described here tackles some of the challenges that exist in the field of neuroscience to advance two important applications: long-term in vivo monitoring in freely-behaving animals using carbon-fiber microelectrodes (CFMs) and high-throughput drug screening using planar microelectrode arrays (MEAs). In particular, a low-power two-step cyclic ADC for wide-range acquisition of neurochemical signals is demonstrated. The system was validated by recording flow-injection of 2-[MICRO SIGN]M dopamine at a CFM using 300-V/s FSCV. A 30-[MICRO SIGN]W wireless microsystem for real-time in vivo monitoring and a lightweight miniaturized device that can enable long-term behavioral studies in freely-behaving animals are also demonstrated. On-chip integration of analog background subtraction and UWB telemetry yields a 32-fold increase in resolution versus stan-  dard Nyquist-rate conversion alone, near a four-fold decrease in the volume of uplink data versus single-bit, third-order, delta-sigma modulation, and more than a 20-fold reduction in transmit power versus narrowband transmission at low data rates. The system was validated by wirelessly recording flow-injection of dopamine with concentrations in the range of 250 nM to 2 [MICRO SIGN]M at a CFM using 300-V/s FSCV. Measurement results indicate an input-referred current noise of 92 pArms and an input current range of ±430 nA at a conversion rate of 10 kHz. A scalable 32 x 32 (1,024-electrode) CMOS VLSI potentiostat array for highthroughput drug screening applications is also presented. The core of the array is a high-precision bidirectional-current detector that enables both amperometry and FSCV using MEAs for massively-parallel detection of transmitter release as well as electrode impedance characterization.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>