<?xml version='1.0' encoding='UTF-8'?><?xml-stylesheet href='static/style.xsl' type='text/xsl'?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-22T08:49:40Z</responseDate><request verb="GetRecord" identifier="oai:ecommons.cornell.edu:1813/3611" metadataPrefix="dim">https://ecommons.cornell.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:ecommons.cornell.edu:1813/3611</identifier><datestamp>2026-05-14T13:54:22Z</datestamp><setSpec>com_1813_35</setSpec><setSpec>col_1813_47</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author">Yeh, Richard Cheng-I</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2006-10-12T13:45:11Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2006-10-12T13:45:11Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2002-01</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="citation" lang="en_US">Yeh, Richard Cheng-I. Master's thesis, Cornell University, 2002.</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://hdl.handle.net/1813/3611</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="bibid">6475870</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">This version is a PDF produced from the source Microsoft Word document. Figure 13, on logical page 36 (PDF page 46), is missing. It was a CorelDraw drawing of the optical layout. Please see the supplemental files "20000710 tweezers1xx AI9.emf" and "20000710 tweezers1xx AI9.ai" for enhanced metafile and Adobe Illustrator 9 versions of that figure.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Feedback-controlled optical tweezers are used to manipulate single biological molecules in experiments on deoxyribonucleic acid (DNA) substrates. Before we trust these measurements, it is essential to know the accuracy and the precision of the device. This thesis describes the design and calibration of the optical tweezers. We measure relative displacements with nanometer accuracy and forces with an accuracy of 10%. The chief source of imprecision is in the human positioning of the sample under study. The capability of the instrument is demonstrated by stretching single molecules of DNA because of the elasticity of DNA has previously been well characterized. This thesis also compares DNA elasticity measurements made on this device with previously published data. I demonstrate that this instrument is well suited for characterizing DNA molecules that are long (~ 4000 bp), but not for DNA that are relatively short (~ 1000 bp). Fit parameters for new DNA tethers containing 4400 base pairs (bp) of DNA agree with expected values. The optical tweezers instrument is accurate enough to determine that one-hour-old 4400-bp DNA tethers have degraded, losing some 4% of their length. Our current methods are not appropriate for measurements of force-extension of short DNA molecules, such as 1155-bp DNA tethers.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="sponsorship" lang="en_US">This work was supported by NIH Molecular Biophysics Training Grant T32 GM08267 and grants to Michelle D. Wang from the NIH and from the Keck Foundation.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent">87332 bytes</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent">67332 bytes</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent">634459 bytes</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/postscript</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/octet-stream</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">en_US</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Cornell University</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">optical tweezers</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">single-molecule</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">feedback</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">DNA stretching</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">calibration</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">error</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">optical trap</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">biophysics</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Design and calibration of optical tweezers for single-molecule studies</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">dissertation or thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">image/x-emf</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/postscript</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="cris" element="virtual" qualifier="collection" authority="https://cornell-ecommons.eks.prod.4science.cloud/handle/1813/47" confidence="600">Cornell Theses and Dissertations</dim:field>
   <dim:field mdschema="cris" element="virtual" qualifier="author">Yeh, Richard Cheng-I</dim:field>
   <dim:field mdschema="cris" element="virtualsource" qualifier="collection">5893a6ea-7af3-41d7-abc6-04bcd26ab5df</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="43819852-6a6d-4f72-937a-a18a51ca4bbc">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>en_US&lt;/Language>
   	&lt;Title>Design and calibration of optical tweezers for single-molecule studies&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2002-01&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Yeh, Richard Cheng-I&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Cornell University&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;Keyword>optical tweezers&lt;/Keyword>
    &lt;Keyword>single-molecule&lt;/Keyword>
    &lt;Keyword>feedback&lt;/Keyword>
    &lt;Keyword>DNA stretching&lt;/Keyword>
    &lt;Keyword>calibration&lt;/Keyword>
    &lt;Keyword>error&lt;/Keyword>
    &lt;Keyword>optical trap&lt;/Keyword>
    &lt;Keyword>biophysics&lt;/Keyword>
   	&lt;Abstract>Feedback-controlled optical tweezers are used to manipulate single biological molecules in experiments on deoxyribonucleic acid (DNA) substrates. Before we trust these measurements, it is essential to know the accuracy and the precision of the device. This thesis describes the design and calibration of the optical tweezers. We measure relative displacements with nanometer accuracy and forces with an accuracy of 10%. The chief source of imprecision is in the human positioning of the sample under study. The capability of the instrument is demonstrated by stretching single molecules of DNA because of the elasticity of DNA has previously been well characterized. This thesis also compares DNA elasticity measurements made on this device with previously published data. I demonstrate that this instrument is well suited for characterizing DNA molecules that are long (~ 4000 bp), but not for DNA that are relatively short (~ 1000 bp). Fit parameters for new DNA tethers containing 4400 base pairs (bp) of DNA agree with expected values. The optical tweezers instrument is accurate enough to determine that one-hour-old 4400-bp DNA tethers have degraded, losing some 4% of their length. Our current methods are not appropriate for measurements of force-extension of short DNA molecules, such as 1155-bp DNA tethers.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>