<?xml version='1.0' encoding='UTF-8'?><?xml-stylesheet href='static/style.xsl' type='text/xsl'?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-22T08:50:13Z</responseDate><request verb="GetRecord" identifier="oai:ecommons.cornell.edu:1813/14033" metadataPrefix="dim">https://ecommons.cornell.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:ecommons.cornell.edu:1813/14033</identifier><datestamp>2026-05-14T13:50:16Z</datestamp><setSpec>com_1813_35</setSpec><setSpec>col_1813_47</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Sung, Jong</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2009-10-14T20:04:39Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2014-10-14T06:24:05Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2009-10-14T20:04:39Z</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://hdl.handle.net/1813/14033</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="bibid">6714432</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Human response to drugs and environmental chemicals is often dramatically different from predictions made by conventional cell-based assays. Current in vitro methods for testing drug toxicity use a single cell type in a static culture environment, treated with a bolus dose. Such experiments do not capture the complex, dynamic response of the body to drug absorption, distribution, metabolism and excretion (ADME). Integrated pharmacokinetic-pharmacodynamic (PK-PD) models allow prediction of pharmacological outcome from a give dosage, but have limitations in building realistic models. A micro cell culture analog (mu-CCA) is a microfluidic device based on a physiologically-based pharmacokinetic (PBPK) model, with multiple chambers each representing an organ or tissue on a silicon chip, with these chambers connected to emulate the blood circulation. This thesis work describes the combined approach of a PK-PD modeling and a mu-CCA platform, for testing the toxicity of chemotherapeutic agents. A PK-PD model was developed to predict tumor growth in a rat, treated with the chemotherapeutic agent, Tegafur. Various dosing scenarios and the effect of metabolizing enzyme levels were tested. As an experimental approach, the mu-CCA was improved in design, to accommodate 3-D hydrogel cell cultures and to enable a long-term operation. Using the mu-CCA, metabolism-dependent toxicity of Tegafur was observed. A PK-PD model for a mu-CCA was developed, and differential responses of three cell lines (representing the liver, tumor, and marrow) to the drugs in static and dynamic conditions were analyzed. A major challenge in developing microfluidic systems is prevention of  bubble formation. A microscale bubble trap was developed, and it was demonstrated that the presence of a bubble trap significantly alleviated the bubble interference. To address the issue of detection and analysis in a microfluidic device, an in situ, fluorescence optical detection system was developed and integrated with a mu-CCA, and a real-time detection of cell viability and metabolic activity was demonstrated. This thesis work demonstrates the use of a microfluidic device, mu-CCA for a pharmacokinetic-based drug toxicity study and its combination with a mathematical modeling for a quantitative analysis of cell death kinetics. We envision that the combined approach will be useful in improving the productivity of drug development process by supplementing animal and human studies.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">en_US</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Pharmacokinetic-Pharmacodynamic Model On A Chip For Testing Toxicity Of Chemotherapeutic Agents</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">dissertation or thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="cris" element="virtual" qualifier="collection" authority="https://cornell-ecommons.eks.prod.4science.cloud/handle/1813/47" confidence="600">Cornell Theses and Dissertations</dim:field>
   <dim:field mdschema="cris" element="virtual" qualifier="author" lang="en_US">Sung, Jong</dim:field>
   <dim:field mdschema="cris" element="virtualsource" qualifier="collection">5893a6ea-7af3-41d7-abc6-04bcd26ab5df</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="b84c6648-16af-45b4-a686-75c72c779b8f">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>en_US&lt;/Language>
   	&lt;Title>Pharmacokinetic-Pharmacodynamic Model On A Chip For Testing Toxicity Of Chemotherapeutic Agents&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2009-10-14T20:04:39Z&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Sung, Jong&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
   	&lt;Abstract>Human response to drugs and environmental chemicals is often dramatically different from predictions made by conventional cell-based assays. Current in vitro methods for testing drug toxicity use a single cell type in a static culture environment, treated with a bolus dose. Such experiments do not capture the complex, dynamic response of the body to drug absorption, distribution, metabolism and excretion (ADME). Integrated pharmacokinetic-pharmacodynamic (PK-PD) models allow prediction of pharmacological outcome from a give dosage, but have limitations in building realistic models. A micro cell culture analog (mu-CCA) is a microfluidic device based on a physiologically-based pharmacokinetic (PBPK) model, with multiple chambers each representing an organ or tissue on a silicon chip, with these chambers connected to emulate the blood circulation. This thesis work describes the combined approach of a PK-PD modeling and a mu-CCA platform, for testing the toxicity of chemotherapeutic agents. A PK-PD model was developed to predict tumor growth in a rat, treated with the chemotherapeutic agent, Tegafur. Various dosing scenarios and the effect of metabolizing enzyme levels were tested. As an experimental approach, the mu-CCA was improved in design, to accommodate 3-D hydrogel cell cultures and to enable a long-term operation. Using the mu-CCA, metabolism-dependent toxicity of Tegafur was observed. A PK-PD model for a mu-CCA was developed, and differential responses of three cell lines (representing the liver, tumor, and marrow) to the drugs in static and dynamic conditions were analyzed. A major challenge in developing microfluidic systems is prevention of  bubble formation. A microscale bubble trap was developed, and it was demonstrated that the presence of a bubble trap significantly alleviated the bubble interference. To address the issue of detection and analysis in a microfluidic device, an in situ, fluorescence optical detection system was developed and integrated with a mu-CCA, and a real-time detection of cell viability and metabolic activity was demonstrated. This thesis work demonstrates the use of a microfluidic device, mu-CCA for a pharmacokinetic-based drug toxicity study and its combination with a mathematical modeling for a quantitative analysis of cell death kinetics. We envision that the combined approach will be useful in improving the productivity of drug development process by supplementing animal and human studies.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>