<?xml version='1.0' encoding='UTF-8'?><?xml-stylesheet href='static/style.xsl' type='text/xsl'?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-21T12:19:45Z</responseDate><request verb="GetRecord" identifier="oai:ecommons.cornell.edu:1813/10135" metadataPrefix="dim">https://ecommons.cornell.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:ecommons.cornell.edu:1813/10135</identifier><datestamp>2026-05-13T16:37:19Z</datestamp><setSpec>com_1813_35</setSpec><setSpec>col_1813_47</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author">Thompson, Megan Elizabeth</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2008-03-04T16:59:42Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2013-03-04T07:22:41Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2008-03-04T16:59:42Z</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://hdl.handle.net/1813/10135</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="bibid">6397092</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">My work has two goals: to develop a method capable of comfortably isolating a single group of muscles to improve in vivo human muscle testing and to investigate how well humans can track target force profiles.&#xd;
&#xd;
I designed, built, and tested a system for isolating leg-extensor muscles (muscles that lift the lower leg) and for measuring knee&#xd;
extension forces during an interactive  tracking experiment featuring computer feedback. The chair was designed to isolate the leg-extensor muscle and to eliminate movement by forming rigid connections to the&#xd;
body. When properly constrained in the chair, the maximum movement observed during "fixed" leg angle experiments was a leg rotation of ~1 degree.&#xd;
&#xd;
In the first force-tracking experiments, the test subject tracked a periodic target force function at a fixed leg angle.  In the second&#xd;
experiments, the subject attempted to match a constant, ramp, or sine wave force profile as her leg angle was being oscillated from 90 degrees to 120 degrees by a motor.  Target wave frequencies for the fixed-angle experiments were 0.10 Hz, 0.25 Hz, 0.50 Hz, 1.00 Hz, and 2.00 Hz; for variable-angle experiments: 0.25 Hz, 0.50 Hz, or 1.00 Hz.&#xd;
&#xd;
Among fixed-angle tests, the lowest RMS error was 4.12%, and the highest was 23.86%. The best variable angle result, obtained while&#xd;
tracking a constant force, was 9.06%.  Error was considerably lower for fixed-angle experiments than it was for variable-angle&#xd;
experiments--the lowest measured error in variable-angle tests was similar to the highest error in fixed-angle tests.  Results generally improved with increasing target force magnitude and worsened with increasing target and forcing frequency.  For fixed-angle tests, conducting additional tests improved accuracy but not precision; the opposite was true for variable-angle tests.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">en_US</dim:field>
   <dim:field mdschema="dc" element="relation" qualifier="isformatof">bibid: 6397092</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">mechanical engineering</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">biomechanics</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">force-tracking</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">limb constraints</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Constraining the Body for Better Force-Tracking Analysis</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">dissertation or thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="cris" element="virtual" qualifier="collection" authority="https://cornell-ecommons.eks.prod.4science.cloud/handle/1813/47" confidence="600">Cornell Theses and Dissertations</dim:field>
   <dim:field mdschema="cris" element="virtual" qualifier="author">Thompson, Megan Elizabeth</dim:field>
   <dim:field mdschema="cris" element="virtualsource" qualifier="collection">5893a6ea-7af3-41d7-abc6-04bcd26ab5df</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="8a307d32-d56d-4963-b402-adffeec6257f">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>en_US&lt;/Language>
   	&lt;Title>Constraining the Body for Better Force-Tracking Analysis&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2008-03-04T16:59:42Z&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Thompson, Megan Elizabeth&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;Keyword>mechanical engineering&lt;/Keyword>
    &lt;Keyword>biomechanics&lt;/Keyword>
    &lt;Keyword>force-tracking&lt;/Keyword>
    &lt;Keyword>limb constraints&lt;/Keyword>
   	&lt;Abstract>My work has two goals: to develop a method capable of comfortably isolating a single group of muscles to improve in vivo human muscle testing and to investigate how well humans can track target force profiles.&#xd;
&#xd;
I designed, built, and tested a system for isolating leg-extensor muscles (muscles that lift the lower leg) and for measuring knee&#xd;
extension forces during an interactive  tracking experiment featuring computer feedback. The chair was designed to isolate the leg-extensor muscle and to eliminate movement by forming rigid connections to the&#xd;
body. When properly constrained in the chair, the maximum movement observed during &amp;quot;fixed&amp;quot; leg angle experiments was a leg rotation of ~1 degree.&#xd;
&#xd;
In the first force-tracking experiments, the test subject tracked a periodic target force function at a fixed leg angle.  In the second&#xd;
experiments, the subject attempted to match a constant, ramp, or sine wave force profile as her leg angle was being oscillated from 90 degrees to 120 degrees by a motor.  Target wave frequencies for the fixed-angle experiments were 0.10 Hz, 0.25 Hz, 0.50 Hz, 1.00 Hz, and 2.00 Hz; for variable-angle experiments: 0.25 Hz, 0.50 Hz, or 1.00 Hz.&#xd;
&#xd;
Among fixed-angle tests, the lowest RMS error was 4.12%, and the highest was 23.86%. The best variable angle result, obtained while&#xd;
tracking a constant force, was 9.06%.  Error was considerably lower for fixed-angle experiments than it was for variable-angle&#xd;
experiments--the lowest measured error in variable-angle tests was similar to the highest error in fixed-angle tests.  Results generally improved with increasing target force magnitude and worsened with increasing target and forcing frequency.  For fixed-angle tests, conducting additional tests improved accuracy but not precision; the opposite was true for variable-angle tests.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >