eCommons

 

Development Of A Miniaturized Electrochemical Pathogen Detection Platform For Micro-Total Analysis Systems

Other Titles

Abstract

This thesis describes a translational research effort to design a portable device, the miniEC, that on its own, is useful for detection of nucleic acids of pathogens and other analytes, but can also be integrated into a complete micro-total analysis system. The design incorporated a microfabricated liposome-amplified biosensor, a potentiostat for electrochemical tests, a liquid crystal display, a pushbutton interface for user input, memory for data storage and a serial connection for networking the device to a PC. In operation, the potentiostat powers the biosensor and is also responsible for amplifying and measuring the sensor’s output. Specificity of the biosensor is ensured by DNA capture and reporter probes that hybridize with the target nucleic acid sequence. The reporter probes are coupled to liposomes entrapping the electrochemically active redox couple, potassium ferri/ferrohexacyanide. The capture probes are coupled to superparamagnetic beads. After hybridization, The liposome-target-bead complexes are captured by a magnet within the biosensor. The liposomes are then lysed to release the electrochemical markers unto an interdigitated ultramicroelectrode array. The redox activity of the markers on the electrodes is measured as a current, that is subsequently displayed and stored by the miniaturized instrumentation. The portable miniEC system replaces electrodes, potentiostat and computer systems in conventional electrochemical set ups. Use of the inexpensive, low-power, powerful and energy efficient MSP430 microcontroller together with other carefully selected, low power, off-the-shelf components, resulted in a design that can run for months on a single AA or AAA battery. Also, emphasis on low cost resulted in a compact design with a minimal number of components, that altogether, cost less than $50 in prototype quantities. The accuracy of the miniEC was evaluated by comparing its performance to a standard bench-top electrochemical workstation in static and dynamic constant current amperometric experiments. In both sets of experiments, the inexpensive miniEC’s performance was comparable in signal strength and sensitivity to that of the electrochemical workstation. It was then successfully used in the detection of dengue fever virus RNA. The design of the biosensor, hardware and embedded software was modular, general and flexible such that differentiated products could easily be generated for applications in different fields within a short development window. We provided an example of such a differentiated product with a step by step enhancement of the basic unit into a 5-channel multi-sensor unit. Applied to Cryptosporidium parvum detection, the multi-sensor miniEC was capable of single oocyst detection.

Journal / Series

Volume & Issue

Description

Sponsorship

Date Issued

2010-04-09T20:20:00Z

Publisher

Keywords

Location

Effective Date

Expiration Date

Sector

Employer

Union

Union Local

NAICS

Number of Workers

Committee Chair

Committee Co-Chair

Committee Member

Degree Discipline

Degree Name

Degree Level

Related Version

Related DOI

Related To

Related Part

Based on Related Item

Has Other Format(s)

Part of Related Item

Related To

Related Publication(s)

Link(s) to Related Publication(s)

References

Link(s) to Reference(s)

Previously Published As

Government Document

ISBN

ISMN

ISSN

Other Identifiers

Rights

Rights URI

Types

dissertation or thesis

Accessibility Feature

Accessibility Hazard

Accessibility Summary

Link(s) to Catalog Record