Optimizing Throughput in a Fetal Cell Magnetophoretic Separator
Loading...
No Access Until
Permanent Link(s)
Collections
Other Titles
Abstract
Magnetophoretic separation is a non-invasive method under development for the sampling of
nucleated fetal red blood cells (NRBCs). By inducing a magnetic field gradient symmetrically about a microfluidic
separatory channel, blood cells may be separated based on their inherent magnetic
properties [1]. Diamagnetic red blood cells (RBCs) are magnetically attracted into lateral side channels, while others cells, e.g. white blood cells (WBCs), are paramagnetic and repelled into the center waste channel. We aimed to model the first phase of a complete lab-on-chip device for the separation of RBCs from maternal circulation in order to isolate NRBCs for fetal diagnostics. Simulation results from COMSOL implementation revealed that seven out of ten RBCs successfully traveled to the intended lateral channels while three out of ten traveled through the center channel. All ten WBCs ended up in the center channel as intended. The three RBCs were collected
in the middle channel due to their starting position. At the center of the channel before the fork, the magnetophoretic force was very weak and close to zero because magnets from both sides of the channel apply a force on those cells. In order to improve the efficiency of the magnetophoretic
separator, the geometry of the channel was changed. An initial bifurcation was implemented that caused unilateral application of the magnetophoretic force before the main channel re-converged.
By doing so, the initial force balance was broken and separation effi ciency was improved from 70% to 90%. Additionally, in order to improve device throughput the inlet velocity was subject to optimization. Using an objective function penalizing loss of RBCs and WBC contamination, an optimum inlet
velocity of 0:875 mm x s-1 was determined. These actions constituted steps in solving the speed and accuracy constraints that have prevented successful commercialization of such a device. In doing so, model validation provided the basis for future manufacturing and testing and satisfied our motivation in developing safer fetal diagnostics.
Journal / Series
Volume & Issue
Description
Sponsorship
Date Issued
2015-05-19
Publisher
Keywords
Computer-Aided Engineering; Biomedical Processes
Location
Effective Date
Expiration Date
Sector
Employer
Union
Union Local
NAICS
Number of Workers
Committee Chair
Committee Co-Chair
Committee Member
Degree Discipline
Degree Name
Degree Level
Related Version
Related DOI
Related To
Related Part
Based on Related Item
Has Other Format(s)
Part of Related Item
Related To
Related Publication(s)
Link(s) to Related Publication(s)
References
Link(s) to Reference(s)
Previously Published As
Government Document
ISBN
ISMN
ISSN
Other Identifiers
Rights
Rights URI
Types
term paper