Show simple item record

dc.contributor.authorFoo, John Chee Keong
dc.date.accessioned2018-10-23T13:23:00Z
dc.date.available2020-06-04T06:00:33Z
dc.date.issued2018-05-30
dc.identifier.otherFoo_cornellgrad_0058F_10883
dc.identifier.otherhttp://dissertations.umi.com/cornellgrad:10883
dc.identifier.otherbibid: 10489523
dc.identifier.urihttps://hdl.handle.net/1813/59438
dc.description.abstractNeurological diseases such as glioblastoma multiforme are difficult to treat because the blood-brain barrier prevents most therapeutic drugs administered through the bloodstream from entering the brain. One way of overcoming this is by infusing the drug directly into the diseased site in the brain using either a needle or a cannula, a technique known as convection-enhanced delivery (CED). CED uses a pressure gradient to disperse the drug farther than if the drug were dispersed solely by diffusion. However, once the drug has been injected into the brain, physicians lose the ability to control the spatial distribution of the drug. Ultrasound focused via time-reversal acoustics (TRA) has been shown to further increase the distribution volume of CED infusions, raising the possibility that TRA-focused ultrasound may be used to direct the distribution of substances infused into brain tissue. In this dissertation, ultrasound focused adjacent to the infusion site did not appear to affect the distribution of Evans blue–labeled bovine serum albumin (EBA) in 0.2% wt/vol agarose gels or in vivo in the caudate putamen of rodent brains. Ultrasound focused at the site of infusion did not affect the distribution volumes of tracers when they were co-infused with microbubbles, but did significantly increase the distribution volume of EBA when it was co-infused with 20-nm, but not 40-nm, polystyrene particles. Results from a diffusion model suggest that ultrasound may have enhanced the convective phase rather than the diffusive phase of these infusions. Examination of rodent brain sections using fluorescence microscopy showed a distribution of EBA interspersed with regions of low Evans blue intensity that coincided with axon bundles, suggesting that the distribution of substances in the caudate putamen is not uniform even within seemingly homogeneous grey matter. This may partially account for the disappointing results from advanced CED clinical trials so far.
dc.language.isoen_US
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 International*
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectteaching
dc.subjectbrain drug delivery
dc.subjectconvection-enhanced delivery
dc.subjectflipped classroom
dc.subjecttime-reversal acoustics
dc.subjectultrasound
dc.subjectBiomedical engineering
dc.titleThe Effects of Ultrasound on Convection-Enhanced Delivery
dc.typedissertation or thesis
thesis.degree.disciplineBiomedical Engineering
thesis.degree.grantorCornell University
thesis.degree.levelDoctor of Philosophy
thesis.degree.namePh. D., Biomedical Engineering
dc.contributor.chairOlbricht, William Lee
dc.contributor.committeeMemberHarris-Warrick, Ronald Morgan
dc.contributor.committeeMemberStroock, Abraham Duncan
dc.contributor.committeeMemberSchaffer, Chris
dcterms.licensehttps://hdl.handle.net/1813/59810
dc.identifier.doihttps://doi.org/10.7298/X4154F8S


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivatives 4.0 International

Statistics