Show simple item record

dc.contributor.authorYeh, Richard Cheng-I
dc.date.accessioned2006-10-12T13:45:11Z
dc.date.available2006-10-12T13:45:11Z
dc.date.issued2002-01
dc.identifier.citationYeh, Richard Cheng-I. Master's thesis, Cornell University, 2002.en_US
dc.identifier.otherbibid: 6475870
dc.identifier.urihttps://hdl.handle.net/1813/3611
dc.descriptionThis version is a PDF produced from the source Microsoft Word document. Figure 13, on logical page 36 (PDF page 46), is missing. It was a CorelDraw drawing of the optical layout. Please see the supplemental files "20000710 tweezers1xx AI9.emf" and "20000710 tweezers1xx AI9.ai" for enhanced metafile and Adobe Illustrator 9 versions of that figure.en_US
dc.description.abstractFeedback-controlled optical tweezers are used to manipulate single biological molecules in experiments on deoxyribonucleic acid (DNA) substrates. Before we trust these measurements, it is essential to know the accuracy and the precision of the device. This thesis describes the design and calibration of the optical tweezers. We measure relative displacements with nanometer accuracy and forces with an accuracy of 10%. The chief source of imprecision is in the human positioning of the sample under study. The capability of the instrument is demonstrated by stretching single molecules of DNA because of the elasticity of DNA has previously been well characterized. This thesis also compares DNA elasticity measurements made on this device with previously published data. I demonstrate that this instrument is well suited for characterizing DNA molecules that are long (~ 4000 bp), but not for DNA that are relatively short (~ 1000 bp). Fit parameters for new DNA tethers containing 4400 base pairs (bp) of DNA agree with expected values. The optical tweezers instrument is accurate enough to determine that one-hour-old 4400-bp DNA tethers have degraded, losing some 4% of their length. Our current methods are not appropriate for measurements of force-extension of short DNA molecules, such as 1155-bp DNA tethers.en_US
dc.description.sponsorshipThis work was supported by NIH Molecular Biophysics Training Grant T32 GM08267 and grants to Michelle D. Wang from the NIH and from the Keck Foundation.en_US
dc.format.extent87332 bytes
dc.format.extent67332 bytes
dc.format.extent634459 bytes
dc.format.mimetypeapplication/postscript
dc.format.mimetypeapplication/octet-stream
dc.format.mimetypeapplication/pdf
dc.language.isoen_USen_US
dc.publisherCornell Universityen_US
dc.subjectoptical tweezersen_US
dc.subjectsingle-moleculeen_US
dc.subjectfeedbacken_US
dc.subjectDNA stretchingen_US
dc.subjectcalibrationen_US
dc.subjecterroren_US
dc.subjectoptical trapen_US
dc.subjectbiophysicsen_US
dc.titleDesign and calibration of optical tweezers for single-molecule studiesen_US
dc.typedissertation or thesisen_US