Cornell University
Library
Cornell UniversityLibrary

eCommons

Help
Log In(current)
  1. Home
  2. College of Agriculture and Life Sciences
  3. PRO-DAIRY
  4. PRO-DAIRY Publications
  5. Dairy Environmental Systems
  6. Simple Cost-Benefit Analyses of Biogas Use and Tariff Options for an Existing Anaerobic Digester System on a New York State Dairy Farm

Simple Cost-Benefit Analyses of Biogas Use and Tariff Options for an Existing Anaerobic Digester System on a New York State Dairy Farm

File(s)
Case Study_CBA of Existing Farm Biogas Use Options_20200701a.pdf (1.33 MB)
Permanent Link(s)
https://hdl.handle.net/1813/72633
Collections
Dairy Environmental Systems
Author
Ray, Lauren
Gooch, Curt
Abstract

New York State (NYS) enacted the Climate Leadership and Community Protection Act (CLCPA) in 2019 that established a renewable energy program under public service law and listed renewable energy systems. This listing resulted in modification of the Value Stack tariff components that are applicable to anaerobic digester gas (ADG)-to-electricity systems, specifically eliminating the Environmental (E) Value component. A set of simple cost-benefit analyses of an existing dairy farm manure ADG-to-electricity system under the historical net energy metering (NEM) tariff, the Value Stack tariff, the Value Stack tariff with the NYS E Value included, and the Value Stack tariff with a calculated E value reflecting total GHG emission reduction revealed that the latter two hypothetical cases produce an annual net income to the farm of $100,000 and $330,000, respectively, while the available NYS tariff options produce none. While the 2,000-cow dairy generates up to 77 percent more electricity than it uses and supplies it to the utility grid, it can only offset its own utility electricity costs with the revenue possible under available NYS tariffs.

Sponsorship
This document was prepared by the Cornell PRO-DAIRY Dairy Environmental Systems Program (aka the Contractor) in the course of performing work contracted for and sponsored by the New York State Energy Research and Development Authority (hereafter “NYSERDA”). The opinions expressed in this report do not necessarily reflect those of NYSERDA or the State of New York, and reference to any specific product, service, process, or method does not constitute an implied or expressed recommendation or endorsement of it. Further, NYSERDA, the State of New York, and the Contractor make no warranties or representations, expressed or implied, as to the fitness for particular purpose or merchantability of any product, apparatus, or service, or the usefulness, completeness, or accuracy of any processes, methods, or other information contained, described, disclosed, or referred to in this report. NYSERDA, the State of New York, and the Contractor make no representation that the use of any product, apparatus, process, method, or other information will not infringe privately owned rights and will assume no liability for any loss, injury, or damage resulting from, or occurring in connection with, the use of information contained, described, disclosed, or referred to in this report.
Date Issued
2020-07
Publisher
Dairy Environmental Systems Program
Keywords
biogas
•
anaerobic
•
digester
•
tarriff
•
electricity
•
value stack
•
net metering
Type
case study
Accessibility Feature
alternativeText
Accessibility Hazard
none