eCommons

 

FULLY-AUTOMATED QUANTITATIVE ANALYSIS OF CARDIAC AND LUNG DISEASES FROM THORACIC LOW-DOSE CT IMAGES

Other Titles

Author(s)

Abstract

Quantitative image biomarkers are emerging as a method for precision medical diagnosis. Fully-automated computer algorithms are explored to provide clinically useful biomarker measurements for the assessment of cardiovascular and lung diseases from low-dose thoracic computed tomography (CT) images. The recent regulatory approval of annual lung cancer screening (LCS) provides the opportunity for the application of these methods to a large at-risk population that will already be receiving annual low-dose chest CT scans. These computer algorithms must specifically address the high image noise levels concordant with the low-dose imaging protocol. Quantitative evaluation of cardiovascular disease is facilitated by automated segmentations of cardiac organs (aorta, heart region, pulmonary trunk); primarily coronary artery calcification (CAC), a major indicator of coronary heart diseases, is scored. For lung disease assessment, the automated detection of interstitial lung disease (ILD) at its earliest detectable stage is performed. In addition, CT image quality (noise and calibration) is automatically assessed from segmented homogeneous regions for quality control and increased measurement precision. Automated CAC scores have shown a 0.90 correlation with reference measurements provided by radiologists. The automated ILD detection algorithm is able to distinguish between early-stage ILD and normal cases with an Area Under the ROC curve of 0.95. The image quality assessment method has also shown to be repeatable and robust when evaluated on phantom images and a large LCS cohort. This research advances the state-of-the-art of computer algorithms for precise region segmentation and biomarker measurements that permit the evaluation of cardiac and lung health in the context of LDCT. The successful outcomes of these algorithms have demonstrated the possibility of automated chest health monitoring on an annual basis for a large population through the LCS process.

Journal / Series

Volume & Issue

Description

Sponsorship

Date Issued

2017-08-30

Publisher

Keywords

Electrical engineering; Cardiac and lung biomarkers; Computer analysis of medical images; Fully-automated CAD; Low-dose CT images; Computer science; Biomedical engineering

Location

Effective Date

Expiration Date

Sector

Employer

Union

Union Local

NAICS

Number of Workers

Committee Chair

Reeves, Anthony P.

Committee Co-Chair

Committee Member

Chen, Tsuhan
Snavely, Keith Noah

Degree Discipline

Electrical and Computer Engineering

Degree Name

Ph. D., Electrical and Computer Engineering

Degree Level

Doctor of Philosophy

Related Version

Related DOI

Related To

Related Part

Based on Related Item

Has Other Format(s)

Part of Related Item

Related To

Related Publication(s)

Link(s) to Related Publication(s)

References

Link(s) to Reference(s)

Previously Published As

Government Document

ISBN

ISMN

ISSN

Other Identifiers

Rights

Rights URI

Types

dissertation or thesis

Accessibility Feature

Accessibility Hazard

Accessibility Summary

Link(s) to Catalog Record